Issue Description: If the TRUMA panel blinks nine times in orange/yellow, it indicates a gas supply error, which may prevent the heater, water, or fridge from operating properly, even if there's enough gas to cook.
Models where it applies: Nomad
Steps to Resolve:
- Check Gas Supply: Ensure that the gas bottle still contains gas. It’s important to verify there’s enough gas as low levels might not sufficiently power all appliances. Remember, even though there might be enough gas to cook, the amount required for heating and refrigeration is significantly higher.
- Verify Connection: Double-check that the gas bottle is connected properly. Ensure the valve on top of the bottle is fully open to allow gas flow.
- Inspect Internal Gas Valves: Depending on your vehicle model, locate and open the internal gas valves:
- Refer to the attached picture of the internal gas valves and confirm they are all in the open position, as indicated by the sticker guidelines.
- Monitor the Panel Indicator: After ensuring all valves are open and the gas bottle is properly connected, check the Truma panel. A steady orange light indicates that the error is being addressed.
- Allow Time for Correction: Please reset the panel and maintain the current setup for 15 to 20 minutes. The yellow light should go from blinking to fixed, signaling that the gas flow has been restored and the water will start to warm, and later turn off.