Truma CP Classic & CP Plus — heater airflow & overheating error (×4 blink)

Your heater has shut itself down because something got too hot — either the warm air can't flow out properly, or the water boiler overheated. Both are usually a quick fix. This is one of the heater's fault signals — for the full list, see the gas or diesel troubleshooting guide.

How it shows on your panel

  • CP Classic (the turn-knob panel): yellow blinks ×4 (or ×6 if it's the water-only version).
  • CP Plus (the screen panel): a code — W18H / E18H / E121H / E150H for airflow, or E151H / E152H for water too hot.

Fix 1 — clear the airflow (the most common cause)

The warm-air outlets are the vents low down around the furniture and floor, and the heater pulls air back in through a larger intake grille. If bedding, bags, or clothes are covering the outlets or the intake, warm air can't circulate and the heater overheats and cuts out.

  • Clear anything sitting on or in front of the outlet vents and the intake grille.
  • Check the floor ducts aren't crushed, kinked, or disconnected.
Truma air outlet

Fix 2 — check the water side (if you're heating water — this is the E151H / E152H case)

If hot water is running while the fresh-water tank is empty, the boiler has nothing to heat, overheats, and shuts down.

  • Switch the heater off and let it cool for a few minutes.
  • Top up the fresh-water tank so the boiler can fill.
  • Don't run water heating with an empty tank.

Then reset

Switch the panel off, wait 5 seconds (give it a few minutes to cool if it was over-temp), and switch it back on. The ×4 blink or the code should clear and the heater restart.