Truma iNET & iNET X Panel (Gas) - Error codes & Troubleshootings

Models where it applies: Nomad / Nomad PopTop / Grand California / Solis / Solis Air

Truma CP plus VarioHeat Operating ...Screens-Panel-Dashboard.2022-05-20-12-34-34.png

 

Related articles:

________________________________________________________________________________________________________________

TRUMA CP PLUS GAS MODEL error codes:

Error code Cause Rectification
W 17 H Hot water mode with empty water container. Switch off Combi and allow to cool. Fill water container with water.
W 18 H Warm-air outlet blocked. Check the individual outlet openings.
E 18 H Circulated air intake blocked. Contact Customer Support
E 21 H Room temperature sensor/cable defective. Contact Customer Support
W 24 H Imminent undervoltage, battery voltage too low < 10.4V. Charge battery 🎥.
E 41 H Electronics blocked. Contact Customer Support
E 43 H Excess voltage > 16.4 V Check battery voltage and power sources, such as battery charger 🎥.
E 44 H Undervoltage, battery voltage too low < 10.0V. Charge battery. If necessary, replace old battery 🎥.

E 112 H
E 202 H
E 121 H
E 211 H

Gas cylinder closed. Check gas supply.
Gas shut-off valve is closed – switch position = off. Open gas shut-off valve – switch position = on.
Overheating protection has responded. Switch off Combi and allow to cool; if necessary, fill the water container with cold water. Check warm air outlets and circulated air intake and remove blockages. Switch Combi on again.
E 122 H
E 212 H
Combustion air infeed or exhaust gas outlet closed. Check for obstructions such as slush, ice or leaves and remove from the openings.
Gas shut-off valve is closed – switch position = off. Open gas shut-off valve – switch position = on.
Gas pressure regulation system defective. Contact Customer Support.
Overheating protection has responded. Switch off Combi and allow to cool; if necessary, fill the water container with cold water. Check warm air outlets and circulated air intake and remove blockages. Switch Combi on again.
Electronics defective. Contact Customer Support.
W 255 H Combi has no 12V DC power supply. Ensure 12V DC power supply 🎥.
No connection between the Combi and control panel. Ensure connection between Combi and control panel.
Control panel cable defective. Contact Customer Support.

 

 

 

 

Was this article helpful?